Typical Case Specifications
Compressor Code
|
M-9.48/(0.5-3.0)-250
|
Compressor Type
|
M Type Horizontal Symmetric Balanced
|
Compressing Stage
|
5
|
Medium
|
Natural Gas
H2S Content ≤ 15ppm,Water Dew Point Satisfies Local Requirement
|
Inlet Temperature
|
20℃
|
Discharge Temperature (After Cooling)
|
≤50℃ (Not exceeding 15℃ of the Ambient Temperature)
|
Inlet Pressure(Gage)
|
0.05-0.3MPa
|
Final Discharge Pressure(Gage)
|
25MPa
|
Discharge Capacity
|
510-1420Nm3/h
|
Shaft Power
|
≤241Kw
|
Main Motor
|
250Kw/380V/457A
Explosion-proof Degree: Exd II BT4
|
Cooling Method
|
Gas: Water Cooling; Cylinder: Natural Cooling
|
Drive Mode
|
Direct by Shaft Coupling
|
Lubrication
|
Cylinder, Packings: Less Oil Lubricated
|
Installation Mode
|
Cabinet/Skid
|
Control Mode
|
PLC + Touch Screen + Soft Start
|
Size, Weight
|
5.2m X 3.1m X 1.8m,12000kg
|